Hits: 1090 img
Put the temperature on the part first. Which location reaches the target temperature, how long it stays there, and what the coating still has to do after it cools.
600 °C can start from a composite coating that already has data on the same duty. At 1000 °C and 1500 °C the centre of the evaluation moves to inorganic or ceramizable systems, and to whether the substrate survives the temperature at all. All three numbers are working conditions. None of them is a temperature grade for a silicone resin.
Resin film means the continuous film left after the coating dries and cures. A composite coating also contains heat-resistant pigments and fillers, and the test result belongs to the whole coating, not to the resin inside it. Ceramization means the material converts on heating into an inorganic residue or a ceramic phase. A residue that is still there afterwards still has to be checked: is it attached, and does it still do the job you needed.
Most heat-data arguments come from mixing these three up. A thermogravimetric residue figure describes mass left in a crucible. It does not describe a film on your part.
|
Part temperature |
Candidate direction |
Check first |
|
600 °C |
Silicone composite coating with data on the same duty |
Thermal cycling or short exposure; after cooling, is it powdery, cracked, or lifting |
|
1000 °C |
Inorganic or ceramizable system |
Oxidation and distortion of the substrate in that atmosphere and dwell; is the converted coating continuous |
|
1500 °C |
Refractory substrate with its matched inorganic system |
Whether the part and substrate combination holds at all; adhesion and protection on the real hot face |
A furnace door outer skin that rises for twenty minutes and a furnace liner that sits on the hot face for a year are two different problems. They will not be answered by the same test, and usually not by the same coating.
State whether the temperature is a flue-gas reading, a controller set point, or a measured part-surface value. Send the dwell time, the atmosphere, and the heating and cooling profile with it. A supplier who receives only "1500 °C" has to guess, and the guess will be conservative in a way that costs you performance, or optimistic in a way that costs you a batch.
A waterborne grade reduces dependence on solvent carriers. It does not remove the need to check the safety data sheet, the drying requirement, and the cure schedule of the specific product.
If the line only air-dries at room temperature, or the oven cannot reach the cure temperature the part needs, fix the process before comparing high-temperature performance. On a thick part the surface can be dry while the interface is not, and the part heats more slowly than a thin test panel. A logged part temperature is worth more than a logged oven set point.
IOTA 6608 / 6609 pure silicone resin emulsions are waterborne film-forming candidates, and their film-forming and application data is the first thing to review if the site requires a water-based route. What the final film does at the target temperature depends on pigments and fillers, dry film thickness, cure, and substrate, as one system.
IOTA 6080 methyl solid silicone resin is available as a different delivery form for comparison. A solid resin is not a direct substitute for a waterborne emulsion.
1. Give the substrate, surface preparation, application method, oven capability, and target dry film thickness.
2. Test on a representative part or panel, at the real temperature, atmosphere, hold and cooling, with repeated cycles where the duty has cycles.
3. Agree in advance what will be checked after cooling: whether colour change is acceptable, how much cracking or lifting is allowed, and how adhesion and protective function will be accepted.
Can a waterborne silicone resin reach 600 °C on its own?
Check the data for the specified composite coating, on your substrate, under your cycling. The delivery form of the emulsion does not prove what the cured film does at 600 °C.
Can 1000 °C and 1500 °C be judged with the same grade?
Evaluate them as two separate duties, with substrate, atmosphere and functional target each time. A short-exposure result does not replace long-term validation.
TGA shows residue. Does that mean the coating has not failed?
TGA gives mass change. Whether the coating still works is decided by cracking, adhesion and the target function on a real panel.
The waterborne film is tack-free. Can we start the heat test?
Confirm cure completion against the technical data first. Surface dryness describes the surface only.
Is the maximum temperature enough for a purchase enquiry?
No. Add the measurement location, dwell time, atmosphere, number of cycles, substrate and acceptance criteria before any two sets of test data can be compared.
If you would like to learn more, you can click below to view: