A specification describes a material, not a finished coating
Technical data sheets are written for the material as supplied or as a reference film, while purchasing decisions concern a finished coating on a specific part. Confusing the two is the most common source of mismatch between a promising sample and a failed trial.
Four categories of information, with different authority
|
Data category |
What it tells you |
What it cannot tell you |
|
Identification |
Chemistry family, reactive group, delivered form |
Whether it suits your substrate |
|
Supply properties |
Non-volatile content, viscosity, solvent, density |
Applied film thickness or coverage |
|
Processing guidance |
Recommended dilution, cure schedule, compatible components |
Whether your equipment reaches those conditions |
|
Reference film data |
Adhesion, hardness, colour, heat ageing on a stated test piece |
Performance in your full system |
Treat the last row with particular care. Reference values are generated on a defined substrate, at a defined thickness, under a defined cure. Change any one of these and the number ceases to describe your situation.
Non-volatile content is not resin content
Two products both quoted at the same non-volatile level may deliver different amounts of active resin per unit of wet coating, because filler, pigment, or additive can sit inside that figure. Before comparing price per kilogram, convert to cost per unit of active resin at the target film build, then check whether application viscosity and pigment-to-binder ratio still meet the formula.
Heat resistance is a test report, not a property
A temperature figure in a data sheet is valid only together with the object tested, the duration, the atmosphere, and the pass criterion. Report a resin tested as a thin film on steel at one hour, and a customer tested as a thick coating on cast iron for a thousand hours, and the two numbers describe different events. Record results for the base resin, a laboratory film, and the customer's complete system as three separate lines.
Checking a data sheet before it turns into a purchase order
· Confirm the test substrate and film thickness behind every mechanical value quoted
· Ask for the cure schedule as a workpiece condition, not only a chamber setpoint
· Check whether listed compatible components were tested in your intended formula or merely in a generic one
· Request safety documentation separately, and confirm storage and shelf-life limits before bulk ordering
Questions that recur
Can reference data be used as an acceptance value? No. It guides sample selection; acceptance requires your own trial on the actual substrate and process.
Is a higher non-volatile figure better value? Only after normalising to active resin and confirming the applied film still meets specification.
Why do two sheets quote incompatible cure times? Different chemistry, catalyst, or film thickness. Each schedule applies to its own product only.
What is missing from most inquiries? Substrate, pretreatment, application method, film thickness, cure capability, and acceptance criteria.